Adaptronic M6000 Modulair ECU
This product is one of the three wire-in universal ECUs we have for our line of Modular ECUs.
Our main objective in creating the Adaptronic Modular ECU line is to further work towards Adaptronic’s mission which is to give people control. In doing this, we came up with a system which would give people greater flexibility and at the same time, overcome the limitations of our older product line - the Select ECUs.
The base M6000 is an ECU that can be expanded to have more analogue 0-5v inputs, real-time / frequency inputs, auxillary outputs, or to be able to control multiple electronic throttles. Injector and Ignition outputs can be expanded up to 24 channels each. There is a total of 6 expansion slots in the M6000 (4 small and 2 large upgrade module slots), and the user may choose which particular board he would need upon purchase or even at a later time. Connectors or looms are sold separately.
What's in the box?
GENERAL FEATURES
- Modular system, so that people can buy hardware upgrades later as their needs develop (eg additional inputs, outputs, or specific functions, eg drive by wire or built-in lambda)
- Offer a waterproof option, using Superseal connectors
-Wireless communication
-Fast USB communication, requiring no drivers
-Headphone port for listening to the knock sensor while tuning
-4 x serial ports
-2 x CAN ports
-Power over USB to do loading of maps, firmware etc without having to provide it with 12V power
- 32MB of onboard logging to flash
-Exception logging, able to detect faults and log a bunch of things that happen around the same time to help with ECU setup and tech support
-Bigger maps, more of them, and more dedicated maps.
-Tested to MIL-STD-202G, a military vibration standard, which varies the frequency and peaks at 7.5g of oscillating acceleration
Features / Specifications
Variable Number Details Analogue 0-5V inputs 11 Each is 0 – 5.5V, 55k input impedance- 2 x TPS / pedal position
- 6 x pressure – Oil, Fuel, Internal intake MAP, internal exhaust MAP, external intake MAP, external exhaust MAP
- 3 x spare for servo feedback / external inputs
- 0 – 5.5V, 55k input impedance
- 0- 3.3V, 1M input impedance
Each can be:
- Non-biased, eg in piggyback mode. Calibration is in mV
- Biased, calibration is in Ohms. 3 internal pull-ups, 1k5, 2k2, 4k7, automatically selected by the ECU
Manifold air temperature, coolant temperature, oil temperature, fuel temperature
Crank trigger inputs 3- Selectable 2k2 pullup (on in digital mode, off in reluctor mode)
- Variable voltage trigger threshold from 0 to 65V – either arm input for reluctor or threshold for digital input
- AC coupled zero crossing trigger in reluctor mode
- Variable filtering 1 to 192 µs
- See built-in scope section
- Selectable 2k2 pullup
- Variable voltage trigger threshold from 0 to 65V
- Variable filtering 1 to 192 µs
- See built-in scope section
- 5V regulated output for sensors, max 100 mA, current limited (voltage is monitored by ECU)
- Sensor ground connected to ground inside ECU under firmware control to detect external ground loops in the wiring (voltage is monitored by ECU)
- 50 k input impedance
- Sampled at 80 kHz (12-bit resolution, 3.3V peak to peak max voltage),
- Variable second order highpass and lowpass filters
- Selectable start and end of sampling windows (in crank angle)
- Dedicated outputs for tacho and EFI relay
- Tacho output has inductor to generate back-EMF spike for impulse tachometers.
- EFI relay output can be configured as fuel pump or EFI relay. Switches to ground, current limited to 600 mA
- Up to 1 Mbps
- Internal 120 Ohm terminating resistor can be turned on and off with ECU setting on each channel
- Standard USB mini AB connector.
- 12 Mbps max speed
- USB appears as mass storage device (USB stick); no drivers are necessary
- Software installer included on mass storage device
- All 4 use 4-pin Molex connectors
- 2 x serial in (ground, transmit, receive)
- 1 x serial out (ground, transmit, receive)
- 1 x controller out (ground, transmit, receive and 12V switched, current limited power) – eg for dash, hand controller
- Access point
- 230kbps max speed
- Settings and live data only (no log retrieval due to speed)
- Microphone
- 3 axis accelerometer
- 3 axis rate gyro
- Max 30 hrs @ 10 Hz, 13 channels
- Min 20 mins @ 100 Hz, 125 channels
- Max sample rate 200 kHz (5µs sample period)
- 1000 samples per screen (min 5ms across the screen)
- Analogue trigger inputs sampled at 40 kHz
Channels include
- Analogue CAS inputs
- Peak detected CAS voltages
- CAS threshold voltages
- Filtered CAS inputs
- Analogue external inputs
- Raw and filtered knock waveforms
- Current engine angle
- Calibrated input values
- Intermediate calculation values
- Output calculated values
Number of injector outputs 8
- Switching topology for low heating
- Peak and hold current waveforms
- Programmable peak and hold current
- Max current per channel 4A continuous
- Nominal current per channel 1A (can be controlled in software)
- Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground
- Output voltage and current monitored
- Appears as a 470 Ohm to supply when high, short to ground when low
- Current limited output
- Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground, and only low current
- Voltage and current monitored
- Push-pull outputs (can drive high or low)
- High side current limited to 1.2A
- Low side current up to 4A continuous
- Can be PWM but not engine synchronous
- Voltage and current monitored
- 4 x Small Modules ( analogue input, real – time input, drive – by – wire control and output module)
- 2 x Large Output Module